LogMeIn support sites no longer support Microsoft's Internet Explorer (IE) browser. Please use a supported browser to ensure all features perform as they should (Chrome / FireFox / Edge).

The GoTo support site no longer supports Safari 15. Please upgrade your browser to Safari 16 (or newer) or switch to a supported browser such as Google Chrome, Mozilla Firefox, or Microsoft Edge.

Anchored by your desk phone? Access your calls, meetings, and messaging on any device. Switch to the GoTo app now.

We are currently experiencing an unplanned outage for this product. View Service Status
  • Support
  • Products

    Explore support by product

    GoTo Connect

    All-in-one phone, meeting and messaging software

    GoTo Meeting

    Video and audio meeting software

    GoTo Webinar

    All-in-one webinar and virtual events software

    GoTo Room

    Conference room hardware

    GoTo Training

    Online training software

    OpenVoice

    Audio conferencing software

    Grasshopper

    Lightweight virtual phone system

    join.me

    Video conferencing software

    LogMeIn Resolve

    IT management & support

    LogMeIn Resolve MDM

    Mobile device management

    LogMeIn Pro

    Remote device access

    LogMeIn Central

    Remote monitoring & management

    LogMeIn Rescue

    Remote IT support

    GoToMyPC

    Remote desktop access

    GoToAssist

    Remote support software

    Hamachi

    Hosted VPN service

    RemotelyAnywhere

    On-prem remote access solution
  • Community
  • Trainings
  • Service Status
  • SMS Registration

    United States carriers are now blocking all unregistered outbound SMS per industry regulations to combat spam. Registration is mandatory for all providers, not just GoTo Connect. Register now to restore or maintain SMS service. GoTo Connect cannot expedite carrier reviews.

    Try the improved My Cases portal

    Easily manage your ticket, track its status, contact us from an existing case, and more.

    Sign in to try
  • Language selector icon Language selector icon
    • English
    • français
    • italiano
    • Deutsch
    • español
    • português
    • Nederlands
  • Contact Support
  • Service Status
  • User Avatar User Avatar
    • Support
    • Contact Support
    • Browse Products
    • Service Status
    • Community
    • Trainings
    • Sign in
    • User Avatar
    • My Account
    • Personal Info
    • Sign In & Security
    • My Cases
    • Billing Center
    • https://link.goto.com/myaccount-billing
    • My GoTo Connect
    • My Meetings
    • My Webinars
    • My Trainings
    • My Conferences
    • My Resolutions
    • My Mobile Devices
    • My Sessions
    • My Sessions
    • My Incidents
    • Sign out
  • Phones and meetings
  • Explore Features
  • Admin portal
  • Devices
  • Devices
product logo
Back button image Back
Back button image
product logo

Provision an analog adapter (ATA)

Configure an analog adapter (ATA) to work with our system, generally for use with an analog fax machine or a paging system.

This is an advanced task. Please reach out to Customer Support for assistance as needed. The following instructions only apply to SPA adapters.

PBX Administration (classic)

If you're an admin who signs in at https://my.jive.com/pbx, these steps are for you.
Before you begin: Verify you have created a device profile and assigned the ATA's MAC address to that profile.
  1. Plug the Ethernet cord into the Internet port and the analog device into the Phone 1 port. Do not use the Phone 2 or Line ports.
  2. Plug in the power adapter.
  3. Obtain the IP address using one of the following options:
    Option Steps
    Analog Phone
    1. Press **** on the analog phone.
    2. When you hear Configuration Menu, press 110#.
    3. Write down the IP Address the phone reads to you.
    Note: If the IP Address is 0.0.0.0, then it is not properly connected to the network.
    Mac Scanner Go to http://www.colasoft.com/mac_scanner/ to find the MAC address for your adapter.
    Ethernet Port — For router devices like the SPA 122 or 232D
    Note: You will need to enable remote management and Bridge Mode on these devices.
    1. Plug the Ethernet cord into the Ethernet port on your computer and on the adapter.
    2. Run ipconfig for windows cmd or ifconfig for mac terminal to find the Ethernet Default Gateway. Cisco SPA122 is defaulted to 192.168.15.1, others are defaulted to 192.168.0.1.
  4. Open an incognito window in Google Chrome, enter the IP address in the address (URL) bar and then press enter on your keyboard. If the web UI doesn't load, enter https:// before the adapter's IP address.
  5. Enter admin for the device username and password.
    Note: If that password does not work, try voipInfo.
  6. Select Voice > Provisioning and then enter http://‹domain›.onjive.com/p/$MA for the Profile Rule.
    Note: Replace ‹domain› with your unique domain (found in parentheses at the top of the admin dashboard).
  7. Select Submit.
What to do next: If the adapter doesn't automatically reboot, power cycle the device to apply its provisioning settings.

Need help?

Contact icon Contact support
Manage Cases icon Manage cases
Community icon Ask the Community
Training icon Attend trainings
Video icon Watch videos
  • Language selector icon Language selector icon
    • English
    • français
    • italiano
    • Deutsch
    • español
    • português
    • Nederlands
  • About Us
  • Terms of Service
  • Privacy Policy
  • Trademark
  • Do Not Sell or Share My Personal Info
  • Browse Products
  • Copyright © 2025 GoTo Group, Inc. All rights reserved

Collaboration Products

GoTo Connect

GoTo Meeting

GoTo Webinar

GoTo Training

join.me

Grasshopper

OpenVoice

Remote Solutions Products

GoTo Resolve

Rescue

GoToAssist

Access Products

Pro

Central

GoToMyPC