LogMeIn support sites no longer support Microsoft's Internet Explorer (IE) browser. Please use a supported browser to ensure all features perform as they should (Chrome / FireFox / Edge).

The GoTo support site no longer supports Safari 15. Please upgrade your browser to Safari 16 (or newer) or switch to a supported browser such as Google Chrome, Mozilla Firefox, or Microsoft Edge.

Anchored by your desk phone? Access your calls, meetings, and messaging on any device. Switch to the GoTo app now.

We are currently experiencing an unplanned outage for this product. View Service Status
  • Support
  • Products

    Explore support by product

    GoTo Connect

    All-in-one phone, meeting and messaging software

    GoTo Meeting

    Video and audio meeting software

    GoTo Webinar

    All-in-one webinar and virtual events software

    GoTo Room

    Conference room hardware

    GoTo Training

    Online training software

    OpenVoice

    Audio conferencing software

    Grasshopper

    Lightweight virtual phone system

    join.me

    Video conferencing software

    LogMeIn Resolve

    IT management & support

    LogMeIn Resolve MDM

    Mobile device management

    LogMeIn Pro

    Remote device access

    LogMeIn Central

    Remote monitoring & management

    LogMeIn Rescue

    Remote IT support

    GoToMyPC

    Remote desktop access

    GoToAssist

    Remote support software

    Hamachi

    Hosted VPN service

    RemotelyAnywhere

    On-prem remote access solution
  • Community
  • Trainings
  • Service Status
  • SMS Registration

    United States carriers are now blocking all unregistered outbound SMS per industry regulations to combat spam. Registration is mandatory for all providers, not just GoTo Connect. Register now to restore or maintain SMS service. GoTo Connect cannot expedite carrier reviews.

    Try the improved My Cases portal

    Easily manage your ticket, track its status, contact us from an existing case, and more.

    Sign in to try
  • Language selector icon Language selector icon
    • English
    • français
    • italiano
    • Deutsch
    • español
    • português
    • Nederlands
  • Contact Support
  • Service Status
  • User Avatar User Avatar
    • Support
    • Contact Support
    • Browse Products
    • Service Status
    • Community
    • Trainings
    • Sign in
    • User Avatar
    • My Account
    • Personal Info
    • Sign In & Security
    • My Cases
    • Billing Center
    • https://link.goto.com/myaccount-billing
    • My GoTo Connect
    • My Meetings
    • My Webinars
    • My Trainings
    • My Conferences
    • My Resolutions
    • My Mobile Devices
    • My Sessions
    • My Sessions
    • My Incidents
    • Sign out
  • Phones and meetings
  • Account and Billing
  • SSO and user provisioning
  • IT Admin Management
  • Active Directory Connector v2
product logo
Back button image Back
Back button image
product logo

Active Directory Connector v2 Requirements

Most large companies use Microsoft Active Directory (AD) to automate changes for user identities and application privileges.

The Active Directory Connector (ADC) receives Active Directory user updates and automatically makes the same changes in your GoTo account.

The ADC accesses all users in selected AD groups containing GoTo users and all users in any subgroups. All new users are added to one of your validated company email domains in the GoTo Admin Center (classic)'s SCIM* service.

* SCIM is the System for Cross-domain Identity Management that defines how user identities are managed across multiple systems, generally over the Internet.

There are 4 areas of requirements to use the Active Directory Connector (ADC) effectively: Accounts, your Active Directory implementation, the Windows requirements for the ADC host machine, and your firewall settings.

Account requirements

  • A GoTo product account with at least one (1) Organization admin who also has a GoTo product admin role

Active Directory requirements

  • An Active Directory environment running Windows Server 2003 (or later) with the latest updates installed.
  • Windows admin account with the "Log on as a service" permission enabled. This account is used for the Active Directory permission section of the ADC software. To enable this permission for the account being used, do the following:
    1. In Windows, search for and select Local Security Policy.
    2. Go to Local Policies > User Rights Assignment.
    3. Right-click Log on as a service  >Properties > Add User or Group.
    4. Add the ADC Service User (e.g., DOMAIN\username).
    5. Go to Check Names > OK > OK > Apply to save your changes.

System requirements

Active Directory Connector v2 System Requirements
Operating System
  • Windows Server 2008 SP 2 or later (not necessarily a domain controller
  • Windows Vista SP 2 or later
Software
  • Microsoft® .NET Framework 4.5 update on the machine where the ADC will run (included in the ADC installer if needed)
Memory
  • 2 GB RAM or more recommended
Available Disk Space
  • 200MB or more (depending on log level and storage period)
Display
  • Minimum 1680 X 1050
Internet Connection
  • Broadband internet connection with 1+ Mbps and ability for the ADC to connect to https://goto-developer.logmeininc.com

Firewall settings

Firewall settings should be configured as follows:

Use Case < Source Server > < Target Server >:< Port >
Interface for provisioning < ADC Server Name > *.getgo.com:443
Interface for logging; < source server > < ADC Server Name > logging.getgo.com:443
Interface for authentication; < source server > < ADC Server Name > *.logmeininc.com:443
Interface for checking new version of ADC; < source server > < ADC Server Name > s3.amazonaws.com:443
Insecure connections < ADC Server Name > Active Directory Domain Controller:389 (LDAP)
Secure connections < ADC Server Name > Active Directory Domain Controller:636 (LDAPS)
Global Catalog, Insecure connections < ADC Server Name > Active Directory Domain Controller:3268 (LDAP)
Global Catalog, Secure connections < ADC Server Name > Active Directory Domain Controller:3269 (LDAPS)

Steps for setting up the Active Directory Connector v2 and managing users in User Sync:

  1. Review the Active Directory Connector v2 requirements
  2. Set up an organization
  3. Install the ADC v2
  4. Configure the ADC v2
  5. Run the ADC v2
  6. Manage User Sync rules
  7. Update the ADC v2 to the latest version (if applicable)
  8. Troubleshoot the ADC v2 (if needed)
Related Articles:
  • Install Active Directory Connector v2
  • Configure the Active Directory Connector v2
  • Run the Active Directory Connector v2

Need help?

Contact icon Contact support
Manage Cases icon Manage cases
Community icon Ask the Community
Training icon Attend trainings
Video icon Watch videos
  • Language selector icon Language selector icon
    • English
    • français
    • italiano
    • Deutsch
    • español
    • português
    • Nederlands
  • About Us
  • Terms of Service
  • Privacy Policy
  • Trademark
  • Do Not Sell or Share My Personal Info
  • Browse Products
  • Copyright © 2025 GoTo Group, Inc. All rights reserved

Collaboration Products

GoTo Connect

GoTo Meeting

GoTo Webinar

GoTo Training

join.me

Grasshopper

OpenVoice

Remote Solutions Products

GoTo Resolve

Rescue

GoToAssist

Access Products

Pro

Central

GoToMyPC